Settings Class |
Namespace: com.gigatms.Parameters.TS800
The Settings type exposes the following members.
Name | Description | |
---|---|---|
![]() | BLE |
Gets the BLE Settings.
|
![]() | BuzzerOperationMode |
Gets the buzzer operation mode.
|
![]() | DeviceId |
Gets the custom device identifier. It is used to distinguish different devices when multiple readers are connected.
|
![]() | EventType |
Output raw data or decoded data when inventory tag.
|
![]() | InventoryActiveMode | |
![]() | InventoryRoundInterval | Waiting time between each inventory round. Valid value ranges form 0 through 254 (0 s ~ 2.54s). Default value Is 0. It Is Not a precise inventory time interval because:
|
![]() | LinkFrequency |
Gets the tag's backscatter link frequency. The default value is 256 kHz.
|
![]() | OutputInterface |
Gets the output interface.
|
![]() | Profile |
Gets the Global frequency regulations for RFID profile. This property is read-only.
|
![]() | QValue |
Gets the starting Gen2 Q for the number of slots in the round. The value ranges from 0 to 15. The default value is 4.
|
![]() | RemoteHost |
Gets or sets the inventory output target TCP server IP and port.
|
![]() | RfPower |
Gets the RF Power strength. The value is ranging from 1 to 27. The default value is 11.
|
![]() | RfSensitivity |
Gets the RF input sensitivity level. The value is ranging from level 1 to 14. The default value is level 6.
|
![]() | RxDecode |
Gets the RF data encoding. The default value is Miller_4.
|
![]() | ScanMode |
Gets the scan mode.
|
![]() | Session |
Gets the Gen2 Session flag to be selected for an inventory round. The default value is S0.
|
![]() | TagPresentedRepeatInterval | Time interval between reader raise a OnTagPresented or OnTagPresentedEx event. This setting control how often to notify that a tag is presented, not how often the reader inventory. Valid values are 1 to 253 (0.1s ~ 25.3s), 0 (immediately) and 254 (Never repeat). Default value is 0. Immediately means reader will raise tag presented event after each inventory round as soon as possible. Never repeat means tag presented event will raise only once until the tag is considered removed and show up again. ![]() |
![]() | TagRemovedThreshold | How many times (offset by 1) of failed inventory round before the tag is considered removed and then raise tag removal event. If Tag Remove Threshold is set to 2, reader will output a tag removal event when an inventoried tag failed to inventory [2-1=1] time. Valid values are 2 ~ 254 (1 time ~ 253 time), [0 or 1] (immediately). Default value is 5. Immediately means reader will raise tag removal event and tag presented event at the same time because [1-1=0] and [0-1=-1]. This setting is used to reduce the false tag removal events. ![]() |
![]() | Target |
Gets the Gen2 Target. Indicates whether the Select modifies a Tag’s SL flag. The default value is A.
|
![]() | TriggerType |
External trigger types that make TS800-60 inventory. Effective only when ScanMode is Trigger_A_LevelControl.
|
![]() | WiFi |
Gets or sets the Wi-Fi Settings.
|