Settings Properties |
The Settings type exposes the following members.
Name | Description | |
---|---|---|
![]() | BarcodeReadFormat |
The boarcode type when the decode format EAN_UPC in Filter or
Priority3_SGTIN in SetOutputTagData(Boolean, TagDecodedData) is enabled.
|
![]() | BLE |
Gets the BLE Settings.
|
![]() | BuzzerOperationMode |
Gets the buzzer beep condition.
|
![]() | DeactivateEpcPrefix |
Gets the deactivate mode EPC prefix. When reader is set to DEACTIVATE mode
with SetInventoryActiveMode(Boolean, ActiveMode), first two bytes of an inventoried tag's EPC will
be modified to DeactivateEpcPrefix.
|
![]() | DeviceId |
Gets the custom device identifier. It is used to distinguish different devices when multiple readers are connected.
|
![]() | EventType |
Output raw data or decoded data when inventory tag.
|
![]() | FieldSeparator |
Gets the keyboard output field separator.
|
![]() | Filter |
Tag decode format priority. Must select at least 1 decode format.
|
![]() | InventoryActiveMode |
Gets the inventory mode.
|
![]() | InventoryRoundInterval | Waiting time between each inventory round. Valid value ranges form 0 through 254 (0 s ~ 2.54s). Default value Is 0. It Is Not a precise inventory time interval because:
|
![]() | LinkFrequency |
Gets the tag's backscatter link frequency. The default value is 256 kHz.
|
![]() | OutputFormat |
Gets the keyboard output GTIN format.
|
![]() | OutputInterfaces |
Data output interface.
TS800-60 can output with keyboard and stream (ex: USB keyboard and USB HID) simultaneously.
Other interface settings are ignored if set to auto.
|
![]() | PostDataDelimiter |
Gets the keyboard output post data delimiter.
|
![]() | Prefix |
Gets the keyboard output prefix.
|
![]() | Profile |
Gets the Global frequency regulations for RFID profile. This property is read-only.
|
![]() | ReactivateEpcPrefix |
Gets the reactivate mode EPC prefix. When reader is set to REACTIVATE mode
with SetInventoryActiveMode(Boolean, ActiveMode), first two bytes of an inventoried tag's EPC will
be modified to ReactivateEpcPrefix.
|
![]() | RemoteHost |
Gets or sets the inventory output target TCP server IP and port.
Effective when the Auto is set to true or
Stream include TCP_Server.
|
![]() | RfPower |
Gets the RF Power strength. The value is ranging from 1 to 27. The default value is 11.
|
![]() | RfSensitivity |
Gets the RF input sensitivity level. The value is ranging from level 1 to 14. The default value is level 6.
|
![]() | RxDecode |
Gets the RF data encoding. The default value is Miller_4.
|
![]() | ScanMode |
Gets the scan mode.
|
![]() | Suffix |
Gets the keyboard output suffix.
|
![]() | TagMemorySelection |
Gets which tag memory bank to output when the decode format RAW_DATA in Filter or
Priority4_RawData in SetOutputTagData(Boolean, TagDecodedData) is enabled.
|
![]() | TagPresentedRepeatInterval | Time interval between reader raise a OnTagPresented or OnTagPresentedEx event. This setting control how often to notify that a tag is presented, not how often the reader inventory. Valid values are 1 to 253 (0.1s ~ 25.3s), 0 (immediately) and 254 (Never repeat). Default value is 254. Immediately means reader will raise tag presented event after each inventory round as soon as possible. Never repeat means tag presented event will raise only once until the tag is considered removed and show up again. ![]() |
![]() | TagProtection |
Gets the reader security mode. Tag will be locked automatically when writing data if enabled.
|
![]() | TagProtectionAccessPassword |
Gets the tag protection access password.
if TagProtection is set to DynamicPassword, tag will be locked automatically when writing data and the tag's access password will
changed to a reader calculated password.
if TagProtection is set to SpecifiedPassword, tag will be locked automatically when writing data and the tag's access password will
changed to the TagProtectionAccessPassword.
|
![]() | TagRemovedThreshold | How many times (offset by 1) of failed inventory round before the tag is considered removed and then raise tag removal event. If Tag Remove Threshold is set to 2, reader will output a tag removal event when an inventoried tag failed to inventory [2-1=1] time. Valid values are 2 ~ 254 (1 time ~ 253 time), [0 or 1] (immediately). Default value is 5. Immediately means reader will raise tag removal event and tag presented event at the same time because [1-1=0] and [0-1=-1]. This setting is used to reduce the false tag removal events. ![]() |
![]() | TransformEpcPrefix |
Gets the Customized read mode EPC prefix.
|
![]() | TransformEpcState |
Gets the setting of Customized read mode. When reader is in Customized read mode and TransformEpcState is CustomizedRead,
a deactivated tag's first two bytes will be replaced (temporary) to TransformEpcPrefix and decoded as a normal SGTIN tag.
|
![]() | TriggerType |
External trigger types that make TS800-60 inventory. Effective only when ScanMode is Trigger_A_LevelControl.
|
![]() | UsbInterface |
Gets the USB Mode.
Note: TS800-60 will disconnect after modify USB Interface.
Note: Keyboard output is disabled when set to VirtualComPort.
|
![]() | WiFi |
Gets or sets the Wi-Fi Settings.
|